Communities

Writing
Writing
Codidact Meta
Codidact Meta
The Great Outdoors
The Great Outdoors
Photography & Video
Photography & Video
Scientific Speculation
Scientific Speculation
Cooking
Cooking
Electrical Engineering
Electrical Engineering
Judaism
Judaism
Languages & Linguistics
Languages & Linguistics
Software Development
Software Development
Mathematics
Mathematics
Christianity
Christianity
Code Golf
Code Golf
Music
Music
Physics
Physics
Linux Systems
Linux Systems
Power Users
Power Users
Tabletop RPGs
Tabletop RPGs
Community Proposals
Community Proposals
tag:snake search within a tag
answers:0 unanswered questions
user:xxxx search by author id
score:0.5 posts with 0.5+ score
"snake oil" exact phrase
votes:4 posts with 4+ votes
created:<1w created < 1 week ago
post_type:xxxx type of post
Search help
Notifications
Mark all as read See all your notifications »
Q&A

Special equipment for Nitrox Dive?

+0
−0

Is there any special equipment needed for diving with Nitrox(more than 21% O2)? In Germany there are regulations and laws that say that you can only dive using Nitrox if you have this special equipment. I did my SSI Nitrox diver in Indonesia, where we used the regular equipment. Also, I've nowhere before heard of this special equipment. Does anyone have experience with this special equipment? And if so, what is it exactly and what does it cost?

History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.
Why should this post be closed?

This post was sourced from https://outdoors.stackexchange.com/q/14569. It is licensed under CC BY-SA 3.0.

0 comment threads

3 answers

+0
−0

The main 'special equipment' is to have an O2 analyser and use it. You should also have waterproof tape (Gaffa tape) and marker pen.

Cylinders should be O2 cleaned according to local regulations (every 15 months in the UK). Regulators don't need to be specialist O2-compatible devices (for example the green ones sold for twice the price of normal regulators). Note that some (expensive) titanium regulators are not recommended for use with 100% oxygen.

Mark up your cylinders with tape on the cylinder neck with the analysed O2 percentage to one decimal place and the date.

Some agencies require the MOD (Max. Operating Depth)

MOD = (1.4 / O2_fraction) - 1

Example: MOD of 32% in metres:

MOD = (1.4 / 0.32) - 1
    = 4.375 - 1
    = 33.75 metres
History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.

This post was sourced from https://outdoors.stackexchange.com/a/19773. It is licensed under CC BY-SA 4.0.

0 comment threads

+0
−0

Yes, and no, it kind of depends on the local laws.

So long as your equipment is covered by your manufacturer guarantee, and you will have to bear in mind as will all diving the local laws and legislations for equipment use in various countries / regions within a country, then it can use a higher FO2 than diving with Air.

However your equipment must be:

  1. Oxygen Clean*.
  2. Use Oxygen Compatible Air.
  3. Be serviced regularly. (I believe with SSI they're making this more frequent)

Specialist Equipment in this sense is where you have separate equipment which does not use regular Air or other mixes. This will be things like:

  1. O rings.
  2. Cylinders.
  3. Regs (first and second stages), etc.

Consider this as having a separate breathing system for higher FO2 mixes.

In some cases this can be your usual equipment after a service + oxygen cleaning. Cost varies.

This information is covered in the SSI Nitrox 32% and 40% courses (at least as of November 2016 for a certainty as that's when I did this course myself).

*Oxygen cleaning is a chemical cleaning, surface preparation service for products intended for use in oxygen. - in short, this is to remove particles etc from your gear, it also means you use oxygen compatible sealants, chemicals etc on the equipment as otherwise friction can cause fire and/or explosions due to the high pressures.

History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.

This post was sourced from https://outdoors.stackexchange.com/a/14570. It is licensed under CC BY-SA 3.0.

0 comment threads

+0
−0

The "special equipment" needed for Nitrox most likely refers to the M26 tank valve fitting, which in certain European countries replaces the classic 5/8" DIN valve for cylinders that are for use with Nitrox (oxygen clean, etc). They are much larger and so a DIN regulator first stage cannot be screwed in, meaning you need special regs for Nitrox too. However most of the world ignored M26 and continues to use the same DIN valve (with or without an insert) for both air and Nitrox. Adaptors between the two standards are available, expect to pay around £20.

History
Why does this post require attention from curators or moderators?
You might want to add some details to your flag.

This post was sourced from https://outdoors.stackexchange.com/a/19834. It is licensed under CC BY-SA 4.0.

0 comment threads

Sign up to answer this question »